中央空调系统设计英文文献和参考文献(7)

时间:2021-12-25 19:28来源:毕业论文
4-10 MK-48 hood sequence afterbody teardown and accessories rooms 4-8 4-11 MK-48 refueling hood 4-9 4-12 Vertical distribution method 4-10 4-13 Horizontal distribution method 4-10 5-1 Floor plan for F

4-10 MK-48 hood sequence afterbody teardown and accessories rooms 4-8

4-11 MK-48 refueling hood 4-9

4-12 Vertical distribution method 4-10

4-13 Horizontal distribution method 4-10

5-1 Floor plan for FRP facility 5-2

5-2 Workbench hood 5-4

5-3 Floor exhaust 5-4

5-4 Spray up booth 5-5

5-5 Ventilated sink 5-5

5-6 Exhaust system schematic 5-7

6-1 Downdraft blast enclosure 6-2

6-2 Crossdraft blast enclosure 6-3

7-1 Floor sweep 7-2

8-1 Ventilation system for battery maintenance facilities 8-2

9-1 Walk-in downdraft paint booth 9-3

9-2 Drive through crossdraft paint booth with mechanical replacement air 9-4

9-3 Drive through crossdraft paint booth with no mechanical replacement air 9-5

9-4 Paint mixing hood and work bench 9-6

10-1 Crossdraft corrosion control hangar 10-2

10-2 Hangar door and exhaust plenum details 10-3

TABLES

3-1 Minimum Volumes and Vacuum Hose Size for Asbestos Operations 3-6

5-1 Recommended Hoods, Capture Velocity and Air Pollution Device 5-3

INTRODUCTION

1-1 SCOPE。 This Unified Facilities Criteria (UFC) provides criteria for the design of ventilation systems that control contaminants generated from industrial processes。

1-2 PURPOSE OF CRITERIA。 Criteria are developed to define requirements during the design of industrial ventilation systems。 Chapter 2 provides general criteria and Chapters 3 through 10 provide criteria for specific processes。 Use the general criteria presented in Chapter 2 along with the applicable specific criteria presented in Chapters 3 through 10 to design the ventilation system。 For all other ventilation applications, use the criteria in Chapter 2。

Criteria contained in this UFC should be interpreted as the minimum required and should be improved where current technology or situation warrants。 Users of this UFC are advised to consult the most current edition of the standards。

This UFC does not incorporate inpidual state and local environmental requirements。 It is the sole responsibility of the cognizant design personnel to design an industrial ventilation system that complies with state and local environmental requirements。 中央空调系统设计英文文献和参考文献(7):http://www.youerw.com/fanyi/lunwen_87300.html